GEA Niro Method No. A 4 a |
|
|
Revised: September 2006 |
|
1.
Definition
The amount of scorched particles
in a powder is determined by comparison with the ADMI chart: 'Scorched Particle
Standards for Dry Milk'.
2.
Scope
This method is used for milk
powder and all other dried dairy products.
3.
Principle
4.
Apparatus
4.1 Original ADMI
chart 'Scorched Particle Standard for Dry Milk' (see Fig.
1).
4.2 Balance,
sensitivity 0.1 g.
4.3 Cenco Mixer,
Cenco Instrumenten B.V, Breda, The Netherlands.
4.4 Standard filter
pads - diameter 32 mm (1¼ "), Lintine brand, milk-cream sediment testers,
Johnson & Johnson.
4.5 Scorched
particles tester - aspirator or pressure type, filtering diameter 28.5 mm
(1⅛"), Nagashima S.S. Ltd.
4.6 Water jet
pump.
5.
Reagents
Defoaming agent – Octylalcohol or
diglycol laurate S.
6.
Procedure
6.1 Weigh out the
correct amount of powder ± 0.1 g:
Non-fat milk:
25.0
g
Whey:  
; 15.0
g
Whole milk:  
; 32.5
g
6.2 Pour the powder
into the blender glass with 250 ml of 18-27°C water.
6.3 Add 2 or 3 drops
of defoaming agent.
6.4 Mix for 60
seconds in the Cenco Mixer.
6.5 Using a vacuum to
filter the solution immediately through the filter in the tester. Rinse the
blender glass with about 50 ml water and filter it through the same
filter.
6.6 Let the filters
dry for 2 hours at approx. 35°C.
6.7 Measurements are
carried out as single determinations.
7.
Results
Compare the results with the
original ADMI standard chart. The comparison is visual. The standard chart is
divided into a scale from A-D, where
A = 7.5
mg
B = 15.0 mg
C = 22.5
mg
D = 32.5
mg
If a sample is classified as being
between two standards it is always set at the highest value. A sketch of the
ADMI chart is shown on Fig. 1.
8.
Reproducibility
Single
determination.
9.
Remarks
9.1 The filtration
(E4) can also be carried out with compressed air.
9.2. The procedure for
caseinate and casein:
9.2.1 Weigh out 25 g powder ± 0.1
g.
9.2.2 Pour the powder into 200 ml sodium
carbonate 9.09% V/W.
9.2.3 Add 300 ml of 18-27°C
water.
9.2.4 Add 2 or 3 drops of defoaming
agent.
9.2.5 Mix for 60 seconds in the Cenco
Mixer.
9.2.6 Use a vacuum to filter the solution immediately through the
filter in the tester. Rinse the blender glass with about 50 ml water and filter
it through the same filter.
9.2.7 Let the filter dry for 2 hours at
approx. 35°C.
9.2.8 Measurements are carried out as
single determinations.
10.
Reference
• GEA Niro Research Laboratory
• ADPI, Bulletin 916. (previously called ADMI, American Dry
Milk Institute)
• Modification of
the Harland-Ashworth method, published by Kuramoto, Jeness, Coulter and Choi.
Journal of Dairy Science 42:28, 1959.